1 Instruction Manual Model 1785B, 1786B, 1787B & 1788 Programmable DC Power Supplies 99 Washington

Page 2 - Content

zero. 7. Ensure that the current can be adjusted from zero to the full rated value. 8. Turn off the power supply and remove the short wire from the

Page 3 - Quick Reference

Bench-top viewing positions Carrying position 1.5 To Rack Mount the Instrument You can mount the power supply in a standa

Page 4 - Introduction

To rack mount two instruments side-by-side, order rack mount kit IT-E151, you needn’t to use the front cover panel.

Page 5 - The Front Panel at a Glance

Voltage <0.05% + 10mV Programming Accuracy, 12months, (@ 25 °C ± 5 °C) ±(% of output+offset) Current <0.2%+10mA Voltage <0.05%+15mV(<20V),

Page 6 - Display annunciators

Environmental Conditions Designed for indoor use in an installation category II, pollution degree 2 environment. Designed to operate at maximum relat

Page 7 - The Rear Panel at a Glance

Chapter 3 Front-panel Operation So far you have learned how to install your power supply and do quick start. During the quick start, you were briefly

Page 8 - Chapter 1 Quick Start

Step2. Press key. Step3. Use the numeric keys to or ? and ? keys to change the voltage value. Step4. Press to confi

Page 9 - 1.2 Output Checkout

Step2. Select >MAX VOLT by using? and ? key. Step3. Press key. Step4. Change the voltage value by using numeric keys to o

Page 10

n Setting Address (>ADDRESS) This instruction can set the communication address for each power supply. The address range is from 0 to 254. Bef

Page 11 - rack mount kit

Chapter 4 Remote Operation Mode The DB9 interface connector on the rear panel of the power supply can be transferred to RS-232 interface, the followi

Page 12 - Chapter 2 Specifications

Content Quick Reference ...

Page 13 - Maximum input power

4.3 Frame format Frame length is 26 bytes, the format is as follows: Start Address Command 4-25 bytes are information content Check sum De

Page 14 - (Unit: mm)

3rd byte Command ( 20H) 4th byte Operation mode(0 represent front panel operation mode, 1 represent remote operation mode) 5th to 25th byte System

Page 15 - ON annunciator will turn on

7th byte The highest byte of output voltage value 8th to 25th byte System reserve 26th byte Check sum 5. Setting the output current (24H)

Page 16 - 3.5 Menu Operation

11th byte To set the low byte of current value 12th byte To set the high byte of current value 13th byte Byte 0 of the maximum voltage value 14th b

Page 17 - ? and ? key

1st byte Start bit(AAH) 2nd byte Address(0~0XFE) 3rd byte Command(28H) 4th byte Calibration protection state 5th byte System reserve 26th byte C

Page 18

13. Sending the actual output current to calibration program (2CH) 1st byte Start bit (AAH) 2nd byte Address(0~0XFE) 3rd byte Command(2CH) 4th

Page 19 - PC Load

2nd byte Address (0~0XFE) 3rd byte Command( 31H) 4th to 8th byte Product model(ASIC code) 9th byte Lower byte of the software version 10th byte

Page 20 - 4.4 Communication protocol

26th byte Check sum Chapter 5 Calibration We suggest you to calibrate the power supply yearly. We provide you a set of

Page 21

5.1 Configuration Start the PC1785B_1788 System, the windows is as follows: The diagram of connecting the multi-meter to the calibrated power supply

Page 22

When you measure the output voltage or short current by the multi-meter, please make sure the value is correct. Otherwise it will cause the calibra

Page 23

Quick Reference About your safety Pease review the following safety precautions before operating our equipment. General information The follow

Page 24

6.3 Functions of PV1785B_1788 Start the software PV1785B_1788, the windows is as follows: 1423586 791011 Configure the software operation enviro

Page 25

6.3.1Configure the system The first step for communication is to configure the system, click Configure button , the windows will display as

Page 26

32 6.3.3 Setting Voltage and current 1. Setting voltage/current by rotary knob Note: Before you set the current an

Page 27 - Chapter 5 Calibration

3. Program setting 6.3.4. GO/NG Test Function Program: Right-click on the Program area, the program tools

Page 28 - 5.4 Finish calibrating

6.3.5 Save and Open To save the program settings, quickly settings, voltage sweep settings and GO/NG settings as PAR file. To open the PAR file fo

Page 29 - 6.2 Installation

To set the X-Axes SpanTo set the Y-Axes SpanTo set the limit positionClick here and move to zoom in/out axes or scroll axesTo set the ring buffer size

Page 30

Limited One-Year Warranty B&K Precision Corp. warrants to the original purchaser that its product and the component parts thereof, will be fr

Page 31

Certification and Warranty Certification We certify that this product met its published specifications at time of shipment from the factory. I

Page 32

The Front Panel at a Glance 34576123457612 ? 10 digits VFD display ? Status information for operating mode and working status ? Power sw

Page 33

Function keys description Set the output voltage value Set the current value Save the present settings to a specified register locatio

Page 34

Link The power supply is in communicationmodeRmt The power supply is in remote mode Cal The power supply is in calibration modeThe function keys ar

Page 35 - Vertical marker

Chapter 1 Quick Start One of the first things you will want to do with your power supply is to become acquainted with the front panel. The ex

Page 36 - Limited One-Year Warranty

1.2 Output Checkout The following procedures check to ensure that the power supply develops its rated outputs and properly responds to operatio